Preventa XCS DMP7005 - Coded magnetic switch 2 NC + 1 NO, 5m
Schneider Electric
Product SKU: XCSDMP7005_AUT Preventa XCS DMP7005 - Coded magnetic switch 2 NC + 1 NO, 5m Schneider Electric
Price:
$103.08 In Stock: 1 pc |
range of product
Telemecanique Safety switches XCS
product or component type
Coded magnetic switch
component name
XCSDMP
design
Rectangular, standard
size
88 x 25 x 13 mm
contacts type and composition
2 NC + 1 NO
contact operation
1 NC staggered
material
Plastic
electrical connection
Pre-cabled
cable composition
6 x 0.25 mm²
cable length
5 m
number of poles
3
approach directions
3 directions
[Ue] rated operational voltage
24 V DC
[Ui] rated insulation voltage
100 V DC
[Sa] assured operating distance
8 mm
[Sar] assured tripping distance
20 mm
maximum [Ie] rated operational current
100 mA
[Uimp] rated impulse withstand voltage
2.5 kV conforming to EN/IEC 60947-5-1
resistance across terminals
10 Ohm
short-circuit protection
500 mA external cartridge fuse type gG (gl)
contacts material
Rhodium
electrical durability
1200000 cycles
maximum switching voltage
100 V DC
switching capacity in mA
0.1...100 mA
insulation resistance
1000 MOhm
breaking capacity
10 VA
switching frequency
150 Hz
safety level
Can reach category 4 with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1
Can reach PL = e with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1
Can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to EN/IEC 61508safety reliability data
B10d = 50000000 value given for a life time of 20 years limited by mechanical or contact wear
enclosure material
Thermoplastic PBT
cable material
PVC
depth
13 mm
height
88 mm
width
25 mm
net weight
0.18 kg
standards
EN/ISO 12100
CSA C22.2 No 14
EN/IEC 60947-5-1
UL 508
EN/IEC 60204-1
ISO 14119product certifications
UL
CSAprotective treatment
TH
ambient air temperature for operation
-25…85 °C
ambient air temperature for storage
-40…85 °C
vibration resistance
10 gn (f= 10…150 Hz) conforming to IEC 60068-2-6
shock resistance
30 gn for 11 ms conforming to IEC 60068-2-27
maximum sensitivity to magnetic fields
0.3 mT
electrical shock protection class
Class II conforming to EN/IEC 61140
IP degree of protection
IP66 conforming to IEC 60529
IP67 conforming to IEC 60529